Calibration Equipments
Calibration Equipments
Contact Type Calibrators
Reliable offers two sorts of contact type calibrators which are Dry Block Temperature Calibrators and Liquid Bath Temperature Calibrators. The choice of the two sorts depends on temperature extend under which adjustment is to performed or the sensors working temperature.
Contact Type Calibrator Models
Liquid Bath Calibrator
Liquid Bath Temperature Calibrators provide high stability, uniformity and accuracy.
Dry Block Calibrator
Dry-block (dry-well) calibrators use pre-drilled metal inserts for inserting the temperature sensor that is being calibrated.
Contact Type Calibrators
Reliable offers two sorts of contact type calibrators which are Dry Block Temperature Calibrators and Liquid Bath Temperature Calibrators. The choice of the two sorts depends on temperature extend under which adjustment is to performed or the sensors working temperature.
Contact Type Calibrator Models:
Liquid Bath Calibrator
Liquid Bath Temperature Calibrators provide high stability, uniformity and accuracy.
Dry Block Calibrator
Dry-block (dry-well) calibrators use pre-drilled metal inserts for inserting the temperature sensor that is being calibrated.
Non Contact Type Calibrators
Non Contact Type Calibrators are widely known as Black Bodies.
Dark Bodies are reference sources utilized for testing infrared frameworks. They are required in industry for adjustment of pyrometers, infrared line scanners or cameras. In labs, they are essential for seats for portrayal of complex optronic frameworks.Reliable offers a wide scope of dark bodies to cover all client’s need.
Non Contact Type Calibrator Models
Climate Chamber (Dual
Black Body Source)
Temperature Range 0 to 70°C
Extended Area
Black Body
Temperature Range 0 to 100°C
Extended Area
Black Body
Temperature Range 50 to 500°C
High Temperature Black
Body Source
Temperature Range 600°C to 3000°C
High Stability Black
Body Furnace
Temperature Range 500°C to 1700°C
High Stability Black
Body Furnace
Temperature Range 500°C to 1500°C
Black
Body
Temperature Range 300°C to 1200°C
Black
Body
Temperature Range 50°C to 500°C
Black
Body
Temperature Range 10°C to 110°C
Portable Black
Body
Temperature Range: Ambient: +5°C to 50°C
High Stability Black
Body Furnace General
Temperature Range: 50°C to 1000°C
Portable Black
Body Calibrator
CALsys 37BB+ calibration source is accurate & stable Portable blackbody specially designed for increasing accuracy of thermal imager based human body temperature monitoring.
Non Contact Type Calibrators
Non Contact Type Calibrators are widely known as Black Bodies.
Dark Bodies are reference sources utilized for testing infrared frameworks. They are required in industry for adjustment of pyrometers, infrared line scanners or cameras. In labs, they are essential for seats for portrayal of complex optronic frameworks.Reliable offers a wide scope of dark bodies to cover all client’s need.
Non Contact Type Calibrator Models:
Climate Chamber (Dual
Black Body Source)
Temperature Range 0 to 70°C
Extended Area
Black Body
Temperature Range 0 to 100°C
Extended Area
Black Body
Temperature Range 50 to 500°C
High Temperature Black
Body Source
Temperature Range 600°C to 3000°C
High Stability Black
Body Furnace
Temperature Range 500°C to 1700°C
High Stability Black
Body Furnace
Temperature Range 500°C to 1500°C
Black
Body
Temperature Range 300°C to 1200°C
Black
Body
Temperature Range 50°C to 500°C
Black
Body
Temperature Range 10°C to 110°C
Portable Black
Body
Temperature Range: Ambient: +5°C to 50°C
High Stability Black
Body Furnace General
Temperature Range: 50°C to 1000°C
Portable Black
Body Calibrator
CALsys 37BB+ calibration source is accurate & stable Portable blackbody specially designed for increasing accuracy of thermal imager based human body temperature monitoring.
Reference Standard Sensors
Thermal (Temperature) calibration is accomplished by lifting (or discouraging) the temperature sensor to a known, controlled temperature and estimating the comparing change in its related electrical boundary (voltage or resisitance).The precisely estimated boundaries contrasted and that of a confirmed reference test; the outright distinction speaks to the alignment mistake. On the off chance that the sensor is associated with an estimating instrument, the sensor and the instrument mix can be adequately adjusted by this procedure.
Reference Standard Sensor Models
Noble Metal Master
Thermocouple
Temperature Range 0°C to 1500°C
High Accuracy Platinum
Resistance Thermometer
Temperature Range: -80 to 400°C
Semi Standard Platinum
Resistance Thermometer
Temperature Range: -200 °C to 670°C
Secondary
Thermocouple
Temperature Range: 0 to 1200 °C
Reference Standard Sensors
Thermal (Temperature) calibration is accomplished by lifting (or discouraging) the temperature sensor to a known, controlled temperature and estimating the comparing change in its related electrical boundary (voltage or resisitance).The precisely estimated boundaries contrasted and that of a confirmed reference test; the outright distinction speaks to the alignment mistake. On the off chance that the sensor is associated with an estimating instrument, the sensor and the instrument mix can be adequately adjusted by this procedure.
Reference Standard Sensor Models:
Noble Metal Master
Thermocouple
Temperature Range 0°C to 1500°C
High Accuracy Platinum
Resistance Thermometer
Temperature Range: -80 to 400°C
Semi Standard Platinum
Resistance Thermometer
Temperature Range: -200 °C to 670°C
Secondary
Thermocouple
Temperature Range: 0 to 1200 °C
Measuring Instruments
Reliable design and manufactures temperature readouts and precision thermometers are utilized for both field also lab applications. These read outs are utilized for both Thermocouple and RTD alignment measures.
Precision
Thermometer
Temperature Range 0°C to 1500°C
Precision
Thermometer
Temperature Range: -200 °C to 670°C
High Accuracy
Temperature Indicator
Temperature Range: -80 to 400°C
Measuring Instruments
Reliable design and manufactures temperature readouts and precision thermometers are utilized for both field also lab applications. These read outs are utilized for both Thermocouple and RTD alignment measures.
Measuring Instruments Models:
Precision
Thermometer
Temperature Range 0°C to 1500°C
Precision
Thermometer
Temperature Range: -200 °C to 670°C
High Accuracy
Temperature Indicator
Temperature Range: -80 to 400°C
Temperature Reference Units
In the event of precise thermocouple estimation, it’s a typical practice to reference the cold junction temperature at ice point (0°C) with the goal that copper leads might be associated with an EMF readout gadget. This system stays away from the remuneration of cold junction temperature at the terminal of read out which may not be steady and the estimation may not be precise.
Temperature Reference Unit Models
Reference Unit
Accuracy ±0.1°C; Stability ±0.03°C
Reference Unit
Accuracy ±0.5°C, Errors can be compensated by adjusting controller setting
Temperature Reference Units
In the event of precise thermocouple estimation, it’s a typical practice to reference the cold junction temperature at ice point (0°C) with the goal that copper leads might be associated with an EMF readout gadget. This system stays away from the remuneration of cold junction temperature at the terminal of read out which may not be steady and the estimation may not be precise.
Temperature Reference Unit Models:
Reference Unit
Accuracy ±0.1°C; Stability ±0.03°C
Reference Unit
Accuracy ±0.5°C, Errors can be compensated by adjusting controller setting
Automatic Calibration Systems
Automatic system permits huge number and various models of electrical sourcing and estimating instruments to be controlled and aligned. The framework equipment is configurable by the administrator based on the particular adjustment to be performed.
Automatic Calibration System Models
Autocal
System
24 Channel Calibration( 12 Thermocouple & 12 RTDs)
Portable Thermocouple
Calibrator
Temperature Range 50°C to 650°C
Portable Thermocouple
and RTD Calibrator
Temperature Range 250⁰C to 1200⁰C
Automatic Calibration Systems
Automatic system permits huge number and various models of electrical sourcing and estimating instruments to be controlled and aligned. The framework equipment is configurable by the administrator based on the particular adjustment to be performed.
Automatic Calibration System Models:
Autocal
System
24 Channel Calibration( 12 Thermocouple & 12 RTDs)
Portable Thermocouple
Calibrator
Temperature Range 50°C to 650°C
Portable Thermocouple
and RTD Calibrator
Temperature Range 250⁰C to 1200⁰C
Customised Calibration Equipments
Peltier Based Temperature
Calibrator
Temperature Range: 0 to 120°C
High Stability Black
Body Furnace
Temperature Range 50°C to 1000°C
High Accuracy Liquid
Calibration Bath
Temperature Range: 50 to 250°C
High Stability Thermostat
Testing Bath
Temperature Range: -40 to 50°C
Portable Dual Dry
Block Calibrator
Temperature Range: -15°C to 350°C
Triple Point Of
Water Cell
High Stability
Portable Black
Body
Temperature Range 50°C to 500°C
Customised Calibration Equipments
Peltier Based Temperature
Calibrator
Temperature Range: 0 to 120°C
High Stability Black
Body Furnace
Temperature Range 50°C to 1000°C
High Accuracy Liquid
Calibration Bath
Temperature Range: 50 to 250°C
High Stability Thermostat
Testing Bath
Temperature Range: -40 to 50°C
Portable Dual Dry
Block Calibrator
Temperature Range: -15°C to 350°C
Triple Point Of
Water Cell
High Stability
Portable Black
Body
Temperature Range 50°C to 500°C