Calibration Equipments

Calibration Equipments

Contact Type Calibrators

Reliable offers two sorts of contact type calibrators which are Dry Block Temperature Calibrators and Liquid Bath Temperature Calibrators. The choice of the two sorts depends on temperature extend under which adjustment is to performed or the sensors working temperature.

Contact Type Calibrator Models

Liquid Bath Calibrator

Liquid Bath Temperature Calibrators provide high stability, uniformity and accuracy.

 

Dry Block Calibrator

Dry-block (dry-well) calibrators use pre-drilled metal inserts for inserting the temperature sensor that is being calibrated.

Contact Type Calibrators

Reliable offers two sorts of contact type calibrators which are Dry Block Temperature Calibrators and Liquid Bath Temperature Calibrators. The choice of the two sorts depends on temperature extend under which adjustment is to performed or the sensors working temperature.

Contact Type Calibrator Models:

Liquid Bath Calibrator

Liquid Bath Temperature Calibrators provide high stability, uniformity and accuracy.

 

Dry Block Calibrator

Dry-block (dry-well) calibrators use pre-drilled metal inserts for inserting the temperature sensor that is being calibrated.

Non Contact Type Calibrators

Non Contact Type Calibrators are widely known as Black Bodies.
Dark Bodies are reference sources utilized for testing infrared frameworks. They are required in industry for adjustment of pyrometers, infrared line scanners or cameras. In labs, they are essential for seats for portrayal of complex optronic frameworks.Reliable offers a wide scope of dark bodies to cover all client’s need.

Non Contact Type Calibrator Models

Climate Chamber (Dual
Black Body Source)

Temperature Range 0 to 70°C

 

Extended Area
Black Body

Temperature Range 0 to 100°C

 

Extended Area
Black Body

Temperature Range 50 to 500°C

High Temperature Black
Body Source

Temperature Range 600°C to 3000°C

 

High Stability Black
Body Furnace

Temperature Range 500°C to 1700°C

 

High Stability Black
Body Furnace

Temperature Range 500°C to 1500°C

Black
Body

Temperature Range 300°C to 1200°C

 

Black
Body

Temperature Range 50°C to 500°C

 

Black
Body

Temperature Range 10°C to 110°C

Portable Black
Body

Temperature Range: Ambient: +5°C to 50°C

 

High Stability Black
Body Furnace General

Temperature Range: 50°C to 1000°C

 

Portable Black
Body Calibrator

CALsys 37BB+ calibration source is accurate & stable Portable blackbody specially designed for increasing accuracy of thermal imager based human body temperature monitoring.

Non Contact Type Calibrators

Non Contact Type Calibrators are widely known as Black Bodies.
Dark Bodies are reference sources utilized for testing infrared frameworks. They are required in industry for adjustment of pyrometers, infrared line scanners or cameras. In labs, they are essential for seats for portrayal of complex optronic frameworks.Reliable offers a wide scope of dark bodies to cover all client’s need.

Non Contact Type Calibrator Models:

Climate Chamber (Dual
Black Body Source)

Temperature Range 0 to 70°C

Extended Area
Black Body

Temperature Range 0 to 100°C

Extended Area
Black Body

Temperature Range 50 to 500°C

High Temperature Black
Body Source

Temperature Range 600°C to 3000°C

High Stability Black
Body Furnace

Temperature Range 500°C to 1700°C

High Stability Black
Body Furnace

Temperature Range 500°C to 1500°C

Black
Body

Temperature Range 300°C to 1200°C

Black
Body

Temperature Range 50°C to 500°C

Black
Body

Temperature Range 10°C to 110°C

Portable Black
Body

Temperature Range: Ambient: +5°C to 50°C

High Stability Black
Body Furnace General

Temperature Range: 50°C to 1000°C

Portable Black
Body Calibrator

CALsys 37BB+ calibration source is accurate & stable Portable blackbody specially designed for increasing accuracy of thermal imager based human body temperature monitoring.

Reference Standard Sensors

Thermal (Temperature) calibration is accomplished by lifting (or discouraging) the temperature sensor to a known, controlled temperature and estimating the comparing change in its related electrical boundary (voltage or resisitance).The precisely estimated boundaries contrasted and that of a confirmed reference test; the outright distinction speaks to the alignment mistake. On the off chance that the sensor is associated with an estimating instrument, the sensor and the instrument mix can be adequately adjusted by this procedure.

Reference Standard Sensor Models

Noble Metal Master
Thermocouple

 

Temperature Range 0°C to 1500°C

High Accuracy Platinum
Resistance Thermometer

Temperature Range: -80 to 400°C

Semi Standard Platinum
Resistance Thermometer

Temperature Range: -200 °C to 670°C

 

Secondary
Thermocouple

Temperature Range: 0 to 1200 °C

 

Reference Standard Sensors

Thermal (Temperature) calibration is accomplished by lifting (or discouraging) the temperature sensor to a known, controlled temperature and estimating the comparing change in its related electrical boundary (voltage or resisitance).The precisely estimated boundaries contrasted and that of a confirmed reference test; the outright distinction speaks to the alignment mistake. On the off chance that the sensor is associated with an estimating instrument, the sensor and the instrument mix can be adequately adjusted by this procedure.

Reference Standard Sensor Models:

Noble Metal Master
Thermocouple

Temperature Range 0°C to 1500°C

High Accuracy Platinum
Resistance Thermometer

Temperature Range: -80 to 400°C

Semi Standard Platinum
Resistance Thermometer

Temperature Range: -200 °C to 670°C

Secondary
Thermocouple

Temperature Range: 0 to 1200 °C

Measuring Instruments

Reliable design and manufactures temperature readouts and precision thermometers are utilized for both field also lab applications. These read outs are utilized for both Thermocouple and RTD alignment measures.

Precision
Thermometer

Temperature Range 0°C to 1500°C

 

Precision
Thermometer

Temperature Range: -200 °C to 670°C

 

High Accuracy
Temperature Indicator

Temperature Range: -80 to 400°C

Measuring Instruments

Reliable design and manufactures temperature readouts and precision thermometers are utilized for both field also lab applications. These read outs are utilized for both Thermocouple and RTD alignment measures.

Measuring Instruments Models:

Precision
Thermometer

Temperature Range 0°C to 1500°C

Precision
Thermometer

Temperature Range: -200 °C to 670°C

High Accuracy
Temperature Indicator

Temperature Range: -80 to 400°C

Temperature Reference Units

In the event of precise thermocouple estimation, it’s a typical practice to reference the cold junction temperature at ice point (0°C) with the goal that copper leads might be associated with an EMF readout gadget. This system stays away from the remuneration of cold junction temperature at the terminal of read out which may not be steady and the estimation may not be precise.

Temperature Reference Unit Models

Reference Unit

Accuracy ±0.1°C; Stability ±0.03°C

 

Reference Unit

Accuracy ±0.5°C, Errors can be compensated by adjusting controller setting

Temperature Reference Units

In the event of precise thermocouple estimation, it’s a typical practice to reference the cold junction temperature at ice point (0°C) with the goal that copper leads might be associated with an EMF readout gadget. This system stays away from the remuneration of cold junction temperature at the terminal of read out which may not be steady and the estimation may not be precise.

Temperature Reference Unit Models:

Reference Unit

Accuracy ±0.1°C; Stability ±0.03°C

Reference Unit

Accuracy ±0.5°C, Errors can be compensated by adjusting controller setting

Automatic Calibration Systems

Automatic system permits huge number and various models of electrical sourcing and estimating instruments to be controlled and aligned. The framework equipment is configurable by the administrator based on the particular adjustment to be performed.

Automatic Calibration System Models

Autocal
System

24 Channel Calibration( 12 Thermocouple & 12 RTDs)

 

Portable Thermocouple
Calibrator

Temperature Range 50°C to 650°C

 

Portable Thermocouple
and RTD Calibrator

Temperature Range 250⁰C to 1200⁰C

Automatic Calibration Systems

Automatic system permits huge number and various models of electrical sourcing and estimating instruments to be controlled and aligned. The framework equipment is configurable by the administrator based on the particular adjustment to be performed.

Automatic Calibration System Models:

Autocal
System

24 Channel Calibration( 12 Thermocouple & 12 RTDs)

Portable Thermocouple
Calibrator

Temperature Range 50°C to 650°C

Portable Thermocouple
and RTD Calibrator

Temperature Range 250⁰C to 1200⁰C

Customised Calibration Equipments

Peltier Based Temperature
Calibrator

Temperature Range: 0 to 120°C

 

High Stability Black
Body Furnace

Temperature Range 50°C to 1000°C

 

High Accuracy Liquid
Calibration Bath

Temperature Range: 50 to 250°C

High Stability Thermostat
Testing Bath

Temperature Range: -40 to 50°C

 

Portable Dual Dry
Block Calibrator

Temperature Range: -15°C to 350°C

 

Triple Point Of
Water Cell

High Stability

Portable Black
Body

Temperature Range 50°C to 500°C

 

Customised Calibration Equipments

Peltier Based Temperature
Calibrator

Temperature Range: 0 to 120°C

High Stability Black
Body Furnace

Temperature Range 50°C to 1000°C

High Accuracy Liquid
Calibration Bath

Temperature Range: 50 to 250°C

High Stability Thermostat
Testing Bath

Temperature Range: -40 to 50°C

Portable Dual Dry
Block Calibrator

Temperature Range: -15°C to 350°C

Triple Point Of
Water Cell

High Stability

Portable Black
Body

Temperature Range 50°C to 500°C